Hall-Effect Current Sensors, Split-Core, 0.83" Loop Diameter, 50A

Model: E-AMP200-SC21

  • Measures both AC and DC currents using a split-core system. Available rated currents: 30A, 50A, 100A, 200A, and 500A. Contact an NTI product consultant for other available ratings between 30A and 500A.
  • Common applications include: monitoring AC variable speed drives, static converters for DC motor drives, battery supplied applications, uninterruptible power supplies (UPS), switched mode power supplies (SMPS), electrochemical systems, and power supplies for welding applications.
  • Loop diameter: 0.83" (21mm).
  • Response time: ?5µS @ 50A/µ S, 10%-90%.
  • Galvanic isolation: 2.5KV @ 50Hz, AC, 1min.
Vergleichen
Projektliste
Produktinformation
Spezifikationen
Zubehör
Dokumente

AC & DC Monitor Hall-Effect Transducers
Hall-Effect Transducers compatible with E-ACDCLM and E-DCLM-6

Includes a 7ft 4-wire cable for connecting to the E-ACDCLM or E-DCLM-6.

  • To extend the distance between the hall-effect sensor and the E-ACDCLM or E-DCLM-6, simply connect longer wires (22AWG) using the included splices.
    • It is recommended to place the E-ACDCLM or E-DCLM-6 as close to the hall-effect sensor as possible. The E-ACDCLM and E-DCLM-6 can be placed up to 1000 ft away from the E-2D/5D/16D unit using CAT5/5e/6 cable.

For more information, visit http://www.networktechinc.com/hall-effect-sensors.html

  • Measures both AC and DC currents using a split-core system. Available rated currents: 30A, 50A, 100A, 200A, and 500A. Contact an NTI product consultant for other available ratings between 30A and 500A.
  • Common applications include: monitoring AC variable speed drives, static converters for DC motor drives, battery supplied applications, uninterruptible power supplies (UPS), switched mode power supplies (SMPS), electrochemical systems, and power supplies for welding applications.
  • Loop diameter: 0.83" (21mm).
  • Response time: ?5µS @ 50A/µ S, 10%-90%.
  • Galvanic isolation: 2.5KV @ 50Hz, AC, 1min.
  • Supply voltage: ±12V, ±15V.
  • Output voltage: ±4V.
  • Power consumption: ?25mA.
  • Comes with two 0.2" (5mm) diameter open-slotted mounting holes.
 