Shure Microflex® MX400SE Series microphones are miniature gooseneck-mounted electret condenser microphones designed for speech and vocal pickup. Their high sensitivity and broad frequency range make them suitable for recording, as well as sound reinforcement applications. MX400SE microphones can be screwed onto a mic stand or the supplied 5/8 inch 27-threaded flange. They can be easily changed from side-exit to bottom-exit to conceal the cable. All models include an in-line preamplifier and a 3 m (10 ft) cable. The Microflex Gooseneck microphones bring a whole new meaning to the word flexible. Beyond their fully adjustable goosenecks lies a new level of flexibility the new Microflex interchangeable condenser microphone cartridge. Designed for easy replacement and available in cardioid polar pattern, the interchangeable cartridge offers wide frequency response and accurate sound reproduction for a broad variety of applications, such as houses of worship, courtrooms and conference centers. Plus, the condenser cartridges fit every model in the new Microflex product line for enhanced convenience and consistent sound.
Recommended for general sound reinforcement applications
Wide dynamic range and frequency response for
accurate sound reproduction across the audio spectrum
Balanced, transformerless output for increased immunity to noise over long cable runs
Supplied shock mount for more than 20dB isolation from surface transmitted noise
Supplied threaded flange mount for permanently securing the microphone to a lectern, pulpit, or conference table
Includes snap-fit foam windscreen, in-line preamplifier, and ten foot (3 meter) cable
Polar/Pickup Pattern - Cardiod
Microphone Type - Condenser
Spec Sheet available - Yes
Operating Temperature (Maximum):
57 C
Operating Temperature (Minimum):
-18 C
Maximum Frequency Response (Bandwidth):
17 kHz
Maximum Frequency Response (Bandwidth):
17000 Hz
Minimum Frequency Response (Bandwidth):
50 Hz
Minimum Frequency Response (Bandwidth):
0.05 kHz
Impedance:
150 ohm
Maximum SPL (Sound Pressure Level):
124.20 dB
Sensitivity:
-35 dB
Signal to Noise Ratio:
66 dB
DC Voltage:
52 Volts
Polar Pattern:
Cardioid
Output Impedance:
Rated at 150 ohms (180 ohms actual) at 1000Hz
Open Circuit Sensitivity:
–35dB (17.8mV) At 1kHz, ref. 1V/Pascal), All settings –12dB at 0 gain, 1 Pascal = 94dB SPL
Maximum SPL:
124.20 dB (1kHz at 1% THD, 1k ohms load), All settings +6dB at 0 gain
Equivalent Output Noise:
28 dB SPL (A-weighted)
Signal to Noise:
66 dB (referenced at 94dB SPL)
Dynamic Range with 1k ohms load:
96.2 dB (100dB at 0 gain)
Pickup Angle:
130 degree (–3dB)
Common Mode Rejection:
45 dB (minimum)
Preamplifier Output Clipping Level:
–6 dBV (0.5V), –12dB at 0 gain (1% THD)
Polarity:
Positive sound pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 of output connector
Power Requirements:
11 to 52V DC phantom, 2mA
Relative Humidity:
0 to 95 %
Certification:
Eligible to bear CE Marking, Conforms to European EMC Directive 89/336/EEC, Meets applicable tests and performance criteria in European Standard EN55103 (1996) parts 1 and 2, for residential (E1) and light industrial (E2) environments